WH-10GEA
Everything for the Dometic WH-10GEA
10 gallon, LP gas + 120V electric, direct spark ignition (DSI), aluminum tank (no anode rod needed). 9 replacement parts listed below.
✓ FIT CHECK
Not sure which part fits? Send us your model and serial number from the data plate and we’ll confirm it before you order.
What’s wrong with your WH-10GEA?
Won’t light / lockout after 3 triesControl Board 91365 →Runs the spark and gas valve. Rule out 12V, gas and the electrode first.
Sparks but no gas flowGas Valve 92200 →Opens when the board calls for heat. Check 12V at the coil first.
Water too hot, or not hot enoughThermostat 91447 →Holds water temperature. Most also include the ECO high-limit.
Works on propane, not electricAC Heating Element 92097 →The 120V element that heats water on shore power.
No power to gas or electric sideSwitch 91230 →Power and element switches wear out and corrode.
Door cracked, faded or lostAccess Door 95500-95505 →Sized by tank and by flush vs. radius style.
Loose door or broken latchDoor Part 92101 →Latches, hinges and frames for the outside access door.
Missing screws, brackets or gasketsHardware 92069 →Brackets, screws, gaskets and covers.Key part numbers for the Dometic WH-10GEA:
| Part | Part number(s) for the WH-10GEA |
|---|---|
| Control Board | 91365 |
| Gas Valve | 92200 |
| Thermostat | 91447 |
| AC Heating Element | 92097 |
| Switch | 91230 |
| Access Door | 95500-95505 |
| Door Part | 92101 |
| Hardware | 92069 |
Find your model and serial number on the data plate, visible with the outside access door open.
Common questions
What control board does the WH-10GEA use?
The Dometic WH-10GEA uses 91365. Before replacing it, confirm 12V at the board, good gas pressure and a clean, correctly gapped electrode.
Does the WH-10GEA need an anode rod?
No. It has an aluminum tank, and the tank itself does the job of an anode. Drain and flush it at least once a year and before freezing weather. Don’t install a metal plug or an aftermarket element in the drain opening.
Why does my WH-10GEA work on propane but not electric?
The usual causes are a burned-out heating element, a failed electric-side thermostat or ECO, a bad switch, or a tripped breaker. Test the element for continuity with the power off. Step-by-step guide.
Where is the model and serial number on the WH-10GEA?
It is on the data plate, visible with the outside access door open. Several parts changed at serial number breaks, so have both numbers ready when you order.