Sale

Dometic

Dometic 92200 Gas Valve and Burner Assembly for WH-10GEA and WH-16GEA XT

(No reviews yet) Write a Review
$129.99
$94.50
(You save $35.49 )
SKU:
92200
Condition:
New
Availability:
1-2 week estimated lead time. Accepting orders now!
Compatible Model #'s:
WH-10GEA, WH-16GEA XT
Adding to cart… The item has been added

Description

Dometic 92200 Gas Valve and Burner Assembly for WH-10GEA and WH-16GEA XT

The Dometic 92200 Gas Valve and Burner Assembly is an OEM replacement gas-system kit for current Dometic 10-gallon WH-series RV water heaters. The assembly controls propane flow and delivers fuel to the burner during the ignition and heating cycle.

When the water heater calls for propane heat, the circuit board sends 12-volt DC power to the solenoid gas valve. The valve opens and allows propane to flow through the burner tube, where it is ignited to heat the water inside the tank. A failed valve, damaged burner tube, or restricted gas-system assembly can prevent ignition, reduce burner performance, or cause repeated shutdowns.

Dometic identifies the 92200 as the 10-gallon gas-system service kit and lists it for both the WH-10GEA and WH-16GEA models. The WH-16GEA XT uses a physical 10-gallon tank with a mixing system that provides up to 16 gallons of effective hot-water output.

Models It Fits

  • Dometic WH-10GEA
  • Dometic WH-16GEA XT

Dometic part number: 92200
Part type: Gas valve and burner assembly
Application: Current Dometic 10-gallon WH-series water heaters
Fuel: LP propane
Control voltage: 12 volts DC

This assembly does not fit the smaller WH-6GA, WH-6GEA, or WH-9GEA XT models. Those water heaters use the Dometic 92100 six-gallon gas-system assembly.

Signs You May Need This Part

  • The water heater sparks but the burner does not ignite
  • Propane does not reach the burner during an ignition attempt
  • The gas valve does not click when the water heater calls for heat
  • The water heater works on electricity but not propane
  • The burner lights only after several ignition attempts
  • The burner operates intermittently or shuts down unexpectedly
  • The water heater repeatedly enters ignition lockout
  • The gas valve receives proper voltage but does not open
  • One or both valve solenoids fail electrical testing
  • The burner flame is weak, uneven, or unstable
  • The burner tube is rusted, obstructed, warped, or physically damaged
  • The gas valve terminals or wiring connections are corroded
  • The existing gas-system assembly is leaking or damaged

Similar symptoms may be caused by low propane pressure, air in the gas line, a dirty burner orifice, low 12-volt power, a damaged ignition electrode, an open thermostat or ECO circuit, poor grounding, or a failed control board. Verify that the valve receives power during the ignition sequence before replacing the assembly.

Estimated Installation Time

Approximately 30 minutes to 1 hour.

Installation time may vary depending on water-heater accessibility, propane-line condition, corrosion, and the condition of the burner mounting hardware. After installation, confirm that the burner is properly aligned, verify a stable blue flame, and inspect all disturbed propane connections for leaks.

Recommended Products